# Fault Codes

> Every Kent G3 status and alarm message — what the display means, the first response, and which flow continues the job.

export const Escalate = () => <div>
    <p><strong>Escalate to Kent New Energy service only</strong> — through your registered Kent
    partner channel or the Kent service desk details on your work order. Do not contact any
    third-party or component-manufacturer support line for a Kent-branded system: tickets outside
    the Kent channel are not tracked, not covered, and can void warranty handling.</p>
  </div>;

export const Applicability = ({labels}) => <div style={{
  border: "1px solid #0057A8",
  borderLeft: "6px solid #0057A8",
  borderRadius: "8px",
  padding: "10px 14px",
  margin: "0.75rem 0 1.25rem 0",
  background: "rgba(0, 87, 168, 0.06)",
  fontSize: "0.9em"
}}>
    <strong style={{
  color: "#0057A8",
  marginRight: "8px"
}}>Applies to:</strong>
    {labels.map(l => <span key={l} style={{
  display: "inline-block",
  border: "1px solid #0057A8",
  borderRadius: "999px",
  padding: "1px 10px",
  margin: "2px 6px 2px 0",
  background: "#ffffff",
  color: "#003F7D",
  fontWeight: 600
}}>{l}</span>)}
  </div>;

export const SITE_NAME = "Kent New Energy Knowledge Base";

<Applicability labels={["Kent G3 Hybrid Inverter", "Kent Lithium Battery"]} />

**Read the message, don't guess it.** Record the exact string from the HMI (including any
`10xx DATA:000x` code) before touching anything, then take the first response below. Where a
row says *Continue in*, that flow — not this table — finishes the job.

<Warning>
  **For trained/authorized installers only.** Any restart follows the official sequence, and
  any cover-off work follows [Isolation & Shutdown](/safety/isolation-and-shutdown) — including
  the 5-minute discharge wait.
</Warning>

<Note>
  **The one-restart rule.** For an alarm message: power off in the correct order, **wait
  5 minutes, restart once**. If the same alarm returns, collect the evidence and escalate —
  repeated power-cycling destroys the diagnostic trail and fixes nothing.
</Note>

## Status messages

These describe an operating state, not a fault — most need no action at all.

| Message           | What it describes                | First response                                                                                                                                                                       | Continue in                                                    |
| ----------------- | -------------------------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ | -------------------------------------------------------------- |
| **Off**           | Control device to shutdown       | Turn the device on in the ON/OFF Setting                                                                                                                                             | [Not Starting](/g3/troubleshooting/not-starting)               |
| **LmtByEPM**      | Output is under external control | Confirm an external EPM/meter is limiting against reverse current; confirm any third-party control; confirm the power-control setting; verify the export settings and meter readings | [Zero Export Failing](/g3/troubleshooting/zero-export-failing) |
| **LmtByDRM**      | DRM function ON                  | No action needed                                                                                                                                                                     | —                                                              |
| **LmtByTemp**     | Over-temperature power limit     | No action needed — normal operation                                                                                                                                                  | —                                                              |
| **LmtByFreq**     | Frequency power limit            | No action needed — normal operation                                                                                                                                                  | —                                                              |
| **LmtByVg**       | Volt-Watt mode active            | Triggered by local safety regulation when grid voltage runs high — generally no action; disabling it sits behind partner-gated settings, so escalate rather than adjust              | [Grid Fault](/g3/troubleshooting/grid-fault)                   |
| **LmtByVar**      | Volt-Var mode active             | Same as LmtByVg — regulation-driven, generally no action; the disable path is partner-gated                                                                                          | [Grid Fault](/g3/troubleshooting/grid-fault)                   |
| **LmtByUnFr**     | Under-frequency limit            | No action needed                                                                                                                                                                     | —                                                              |
| **Standby**       | Bypass run                       | No action needed                                                                                                                                                                     | —                                                              |
| **StandbySynoch** | Off-grid → on-grid transition    | No action needed                                                                                                                                                                     | —                                                              |
| **GridToLoad**    | Grid supplying the load          | No action needed                                                                                                                                                                     | —                                                              |

## Alarm messages — grid & AC

| Message                            | What it means                              | First response                                                                                | Continue in                                      |
| ---------------------------------- | ------------------------------------------ | --------------------------------------------------------------------------------------------- | ------------------------------------------------ |
| **Surge Alarm**                    | On-site grid surge                         | Grid-side fault — one restart; persists → Kent service                                        | [Grid Fault](/g3/troubleshooting/grid-fault)     |
| **OV-G-V01 / OV-G-V04**            | Grid voltage above the upper range         | Confirm whether the grid is abnormal; confirm the AC cable is properly connected; one restart | [Grid Fault](/g3/troubleshooting/grid-fault)     |
| **UN-G-V01 / UN-G-V02**            | Grid voltage below the lower range         | Same grid + AC-cable + one-restart sequence                                                   | [Grid Fault](/g3/troubleshooting/grid-fault)     |
| **OV-G-F01 / OV-G-F02**            | Grid frequency above the upper range       | Same grid + AC-cable + one-restart sequence                                                   | [Grid Fault](/g3/troubleshooting/grid-fault)     |
| **UN-G-F01 / UN-G-F02**            | Grid frequency below the lower range       | Same grid + AC-cable + one-restart sequence                                                   | [Grid Fault](/g3/troubleshooting/grid-fault)     |
| **G-PHASE**                        | Unbalanced grid voltage                    | Same grid + AC-cable + one-restart sequence                                                   | [Grid Fault](/g3/troubleshooting/grid-fault)     |
| **G-F-GLU**                        | Grid voltage/frequency fluctuation         | Same grid + AC-cable + one-restart sequence                                                   | [Grid Fault](/g3/troubleshooting/grid-fault)     |
| **NO-Grid**                        | No grid                                    | Restore the AC path — breaker, terminations, cable                                            | [Not Starting](/g3/troubleshooting/not-starting) |
| **OV-G-V02 / OV-G-V03**            | Grid transient overvoltage                 | One restart; confirm whether it continues                                                     | [Grid Fault](/g3/troubleshooting/grid-fault)     |
| **OV-G-V05**                       | Grid voltage RMS instantaneous overvoltage | One restart; confirm whether it continues                                                     | [Grid Fault](/g3/troubleshooting/grid-fault)     |
| **IGFOL-F**                        | Grid current tracking failure              | One restart; confirm whether it continues                                                     | [Grid Fault](/g3/troubleshooting/grid-fault)     |
| **OV-G-I** `(1018 DATA:0000)`      | A-phase RMS overcurrent                    | Confirm the grid; confirm the AC cable connection; one restart                                | [Grid Fault](/g3/troubleshooting/grid-fault)     |
| **GRID-INTF.** `(1030 DATA:0000)`  | AC hardware overcurrent (abc phase)        | One restart; confirm whether it continues                                                     | [Grid Fault](/g3/troubleshooting/grid-fault)     |
| **DCInj-FAULT** `(1037 DATA:0000)` | DC component of current over limit         | Confirm the grid; confirm the AC cable connection; one restart                                | [Grid Fault](/g3/troubleshooting/grid-fault)     |
| **GRID-INTF02** `(1046 DATA:0000)` | Power grid disturbance 02                  | Confirm whether the grid is seriously distorted; check the AC cable is reliably connected     | [Grid Fault](/g3/troubleshooting/grid-fault)     |

## Alarm messages — battery

| Message                                      | What it means                               | First response                                                                                                                               | Continue in                                                      |
| -------------------------------------------- | ------------------------------------------- | -------------------------------------------------------------------------------------------------------------------------------------------- | ---------------------------------------------------------------- |
| **NO-Battery**                               | Battery not connected                       | Verify battery voltage is within standards on the information page; measure battery voltage at the plug                                      | [Comm Fault](/g3/troubleshooting/comm-fault)                     |
| **BatName-FAIL**                             | Wrong battery brand selection               | Confirm the battery model selection matches the actual pack                                                                                  | [Comm Fault](/g3/troubleshooting/comm-fault)                     |
| **CAN Fail**                                 | Inverter–battery communication failure      | Check cable condition; confirm the cable sits in the CAN port at both battery and inverter; confirm it is the right (pairing-specific) cable | [Comm Fault](/g3/troubleshooting/comm-fault)                     |
| **OV-Vbatt**                                 | Battery overvoltage detected                | Verify battery voltage is within standards; measure at the inverter connection point; battery-side follow-up is a battery-service case       | [Battery Not Charging](/g3/troubleshooting/battery-not-charging) |
| **UN-Vbatt**                                 | Battery undervoltage detected               | One restart; persists → Kent service                                                                                                         | [Battery Not Charging](/g3/troubleshooting/battery-not-charging) |
| **OV-Vbatt-H / OV-BUS-H** `(1051 DATA:0000)` | Battery overvoltage hardware failure / VBUS | Check whether the battery circuit breaker is tripping; check whether the battery is damaged                                                  | [When to Escalate](/troubleshooting/when-to-escalate)            |

## Alarm messages — backup

| Message                        | What it means            | First response                                                                                                      | Continue in                                                  |
| ------------------------------ | ------------------------ | ------------------------------------------------------------------------------------------------------------------- | ------------------------------------------------------------ |
| **OV-Vbackup**                 | Inverting overvoltage    | Check the backup port wiring; one restart                                                                           | [Backup Not Working](/g3/troubleshooting/backup-not-working) |
| **Over-Load**                  | Load overload fault      | Backup load power (or an inductive load's start-up power) too large — remove some backup load or the inductive load | [Backup Not Working](/g3/troubleshooting/backup-not-working) |
| **OV-ILLC** `(1052 DATA:0000)` | LLC hardware overcurrent | Check whether the backup load is overloaded; one restart                                                            | [Backup Not Working](/g3/troubleshooting/backup-not-working) |

## Alarm messages — PV & leakage

| Message                                    | What it means                                  | First response                                                                                                                 | Continue in                                                |
| ------------------------------------------ | ---------------------------------------------- | ------------------------------------------------------------------------------------------------------------------------------ | ---------------------------------------------------------- |
| **OV-DC01** `(1020 DATA:0001)`             | DC 1 input overvoltage                         | Check whether the PV voltage is abnormal; one restart                                                                          | [Not Starting](/g3/troubleshooting/not-starting)           |
| **OV-DC02** `(1020 DATA:0002)`             | DC 2 input overvoltage                         | Check whether the PV voltage is abnormal; one restart                                                                          | [Not Starting](/g3/troubleshooting/not-starting)           |
| **PV ISO-PRO01** `(1033 DATA:0001)`        | PV negative ground fault                       | Check the strings for insulation problems; check the PV cable for damage                                                       | [Nuisance Tripping](/g3/troubleshooting/nuisance-tripping) |
| **PV ISO-PRO02** `(1033 DATA:0002)`        | PV positive ground fault                       | Check the strings for insulation problems; check the PV cable for damage                                                       | [Nuisance Tripping](/g3/troubleshooting/nuisance-tripping) |
| **ILeak-PRO01–04** `(1034 DATA:0001–0004)` | Leakage current failure (30/60/150 mA classes) | Check current leakage to ground; verify the grounding; verify all wires are sound and not leaking to ground                    | [Nuisance Tripping](/g3/troubleshooting/nuisance-tripping) |
| **ILeak\_Check** `(1039 DATA:0000)`        | Leakage current sensor failure                 | One restart; persists → Kent service                                                                                           | [When to Escalate](/troubleshooting/when-to-escalate)      |
| **AFCI-Check** `(1040 DATA:0000)`          | AFCI self-test failure                         | One restart; persists → Kent service                                                                                           | [Not Starting](/g3/troubleshooting/not-starting)           |
| **ARC-FAULT** `(1041 DATA:0000)`           | AFCI failure (arc detected)                    | Verify PV connections are tight; further arc-fault adjustment sits behind partner-gated settings — escalate rather than adjust | [Not Starting](/g3/troubleshooting/not-starting)           |

## Alarm messages — internal & hardware

| Message                              | What it means                           | First response                                                                                    | Continue in                                           |
| ------------------------------------ | --------------------------------------- | ------------------------------------------------------------------------------------------------- | ----------------------------------------------------- |
| **Fan Alarm**                        | Fan alarm                               | Check whether the internal fan is working correctly or jammed                                     | [When to Escalate](/troubleshooting/when-to-escalate) |
| **OV-BUS** `(1021 DATA:0000)`        | DC bus overvoltage                      | One restart; persists → escalate                                                                  | [When to Escalate](/troubleshooting/when-to-escalate) |
| **UN-BUS01** `(1023 DATA:0001)`      | DC bus undervoltage                     | One restart; persists → escalate                                                                  | [When to Escalate](/troubleshooting/when-to-escalate) |
| **UNB-BUS** `(1022 DATA:0000)`       | DC bus unbalanced voltage               | One restart; persists → escalate                                                                  | [When to Escalate](/troubleshooting/when-to-escalate) |
| **UN-BUS02** `(1023 DATA:0002)`      | Abnormal DC bus voltage detection       | One restart; persists → escalate                                                                  | [When to Escalate](/troubleshooting/when-to-escalate) |
| **DC-INTF.** `(1027 DATA:0000)`      | DC hardware overcurrent (1–4)           | Check the DC wires are connected correctly with no loose connection                               | [When to Escalate](/troubleshooting/when-to-escalate) |
| **OV-DCA-I** `(1025 DATA:0000)`      | DC 1 average overcurrent                | One restart; persists → escalate                                                                  | [When to Escalate](/troubleshooting/when-to-escalate) |
| **OV-DCB-I** `(1026 DATA:0000)`      | DC 2 average overcurrent                | One restart; persists → escalate                                                                  | [When to Escalate](/troubleshooting/when-to-escalate) |
| **IGBT-OV-I** `(1048 DATA:0000)`     | IGBT overcurrent                        | One restart; persists → escalate                                                                  | [When to Escalate](/troubleshooting/when-to-escalate) |
| **OV-TEM** `(1032 DATA:0000)`        | Module over-temperature                 | Check the surroundings for poor heat dissipation; confirm the installation meets the requirements | [When to Escalate](/troubleshooting/when-to-escalate) |
| **RelayChk-FAIL** `(1035 DATA:0000)` | Relay failure                           | One restart; persists → escalate                                                                  | [When to Escalate](/troubleshooting/when-to-escalate) |
| **UN-TEM** `(103A DATA:0000)`        | Low-temperature protection              | Check the working-environment temperature; one restart                                            | [When to Escalate](/troubleshooting/when-to-escalate) |
| **12Power-FAULT** `(1038 DATA:0000)` | 12 V undervoltage failure               | One restart; persists → escalate                                                                  | [When to Escalate](/troubleshooting/when-to-escalate) |
| **INI-FAULT** `(1031 DATA:0000)`     | AD zero drift overlink                  | One restart; persists → escalate                                                                  | [When to Escalate](/troubleshooting/when-to-escalate) |
| **DSP-B-FAULT** `(1036 DATA:0000)`   | Master–slave DSP communication abnormal | One restart; persists → escalate                                                                  | [When to Escalate](/troubleshooting/when-to-escalate) |

## Before you call Kent service

Have ready: the unit's **serial number**, the **installation date**, the **exact message**
(with any `10xx DATA` code) and a **photo of the screen**, a description of the problem with
pictures, and the **PV array configuration** (panel count and capacity, number of strings).
The Kent service contact and case checklist are on
[When to Escalate](/troubleshooting/when-to-escalate).

<Escalate />